The Cable Code
activeReads a cable type designation (NYY-J 3x1,5, N2XSEYRY, H07RN-F 3G2,5, 12/2 NM-B, Cat6A S/FTP...) in 71 coding systems: 25 national and international letter-code systems and 46 type-name tables (NEC / UL (USA), CSA (Canada), NOM / NMX (Mexico), IRAM / Mercosur (Argentina), ABNT NBR (Brazil), NTP (Peru), NTC / RETIE (Colombia), NCh / SEC (Chile), PN (Poland), CSN (Czech Republic, Slovakia), GOST…
Not seen in any discovery source since 2026-10-31.
- Transactions · 30d
- 0
- Volume · 30d
- $0.00
- Unique buyers · 30d
- 0
- Uptime · 30d
- 93.1%
- Latency p50
- 293ms
Endpoints (15 live)
POST/api/v1/tender— Read a project or tender document (a purchase or project specification, a tender volume, a GTP / data schedule; a PDF of up to 80 pages and 20 MB, or its text) and answer what it asks for: every cable it lists built as a design by the designer's rules and checked against its rule set, the required / offered schedule beside the document's own required values with their pages, each requirement mapped to a requirement card or listed as having none, the conflicts (one parameter with two values, a printed construction against a requirement, a value against the standard the document names, a voltage outside IEC 60038, a schedule row with no construction) and the missing sections. An LLM (Claude) copies the document's values and pages; it decides nothing: every design, check, conflict and gap is the deterministic rules with their sources. A reading takes up to a few minutes, so the call starts a job and answers a poll link; the reading is held in memory for one hour, then gone, and the file is never stored. The poll answer (thecablecode.tender/v1) has job, status (running, done or failed), pages and, when done, the reading; a failed paid reading starts again with the same file at no charge, and the same file within the hour is the same job, not charged twice. For one cable use design_cable or check_cable; for one maker's datasheet, extract_datasheet. $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages; no free allowance. (4 USDC on Base)POST/api/v1/degas— The Pro degassing estimate (research/degassing/PLAN.md): how many days an XLPE core stays in the oven until a share of its crosslinking by-product is left, by Fick diffusion with published coefficients (Polymers 11 (2019) 1439; the methane D0 and Ea of IEEE PES T&D 2016 as quoted there; Electric Wire & Cable 2025 at 65 C), never a standard's result: no standard gives a degassing formula, time or residual limit. The answer is a band (an open conductor with the 2025 coefficient to a sealed conductor with the 2016 one), the cases at 50, 20, 10 and 5 % left, the curve, the highest local share, the time at 60, 65, 70 and 80 C, each step with its source and seen level, the notes and the warnings (drum turns, sheath, uniform start, no chemistry). For MV (up to 46 kV) the AEIC CS8-20 cl. 10.2 wait is given beside it as the standard's printed value (cs8), with the model's residual at its conditions. A factory measurement (input.calibration) fits an effective coefficient and replaces the band. Always paid, at its own price: on the site a member's calculation with no free part. $5.00 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $5.00 per item, one payment. (5 USDC on Base)POST/api/v1/iec60287— The Enterprise IEC 60287 calculation: the continuous current rating of one circuit of three single cores of a medium or high voltage design, in trefoil or flat, buried direct, in buried ducts (one cable in each) or in free air, bonded at both ends, single-point or cross-bonded, at the site conditions sent (IEC 60287-1-1:2006+A1:2014 and IEC 60287-2-1:2015, read at standard level page by page): every step (the a.c. resistance with ys and yp, the dielectric loss, the screen loss factors, T1, T3, T4, the losses) with its value, unit, clause and page, the notes on what was taken and, where no rating is given, the reasons. Where the site is unknown, the values of IEC 60287-3-1:2017, 4.2, Tables 1 and 2, p. 7 stand (1 m, ground 20 °C, air 25 °C, soil 1.0 K·m/W). Also a three-core MV or HV cable (T1 by 4.1.2.2.4 with the 5.3 factor), armour (lambda2, 2.4; T2), corrugated sheaths, a Milliken copper conductor by its wires, partial drying out of the soil (1.4.2.1), and with input.cycle the IEC 60853 cyclic rating (cyclic: the peak of a 24 h load curve, Part 1 up to 36 kV, Part 2 above), with input.emergency the IEC 60853-2 clause 8 emergency rating (emergency; a single core without armour also below 1/3 T.Q, from 10 min, by 4.3). Also ducts in a concrete bank (IEC 60287-2-1 4.2.7.4), a sand-filled or an unfilled trough (4.2.6), identical circuits side by side (4.2.3.3.1) and a heat source crossing the route (IEC 60287-3-3:2007, the derating factor DF). Also three-core cables with sector-shaped copper conductors (IEC 60287-1-1 2.1.4.2, 2.3.8, 2.4.2.3.2; IEC 60287-2-1 4.1.2.2.6, 4.1.2.3.3 with the 5.5 screening factor; steps secG, secK). Not covered: aluminium sector conductors (IEC 60287-1-1 Table 2 has no row), interlocked armour (no strip thickness held), groups of circuits in free air (IEC 60287-2-2), and the cyclic and emergency ratings with a bank, a trough, a group or a crossing. Always paid, at its own Enterprise-grade price: on the site an Enterprise member's calculation. $5.00 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $5.00 per item, one payment. (5 USDC on Base)POST/api/v1/equivalence— The Pro equivalence report (server/pro/equivalence.ts, as a member downloads it under the equivalents panel): an IEC power cable in mm² against its North American counterpart in the same role (low voltage: XHHW-2 or USE-2 / RHW-2 (UL 44) or THHN / THWN-2 (UL 83) at the smallest AWG / kcmil size whose area is at least the IEC section; medium voltage: UL 1072 MV-105, the conductor compared, the wall not), value by value: conductor size and resistance (IEC 60228:2004, NEC Chapter 9 Table 8), insulation wall, voltage, normal temperature (IEC 60502-1 / -2 Table 3, NEC Table 310.16), the compound limits (IEC 60502-1 Table 15, UL 1581 Tables 50.231 and 50.182) and the flame tests (IEC 60332-1-2 against VW-1, IEC 60332-3-24 against FT4: not equivalent), each with its source and seen level, as lines and as the report file (Markdown or plain text). Never a statement that the two are interchangeable: the buyer's specification decides. For a quick verdict across many countries' standards use find_equivalents (cheaper, on the decodes' allowance); this report is the one IEC to NEC / UL pair, value by value. Always paid: the site gives it to members only. $0.50 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/extract— Read a power cable datasheet (a maker PDF, an https link to one, or pasted datasheet or tender text) into constructions: every cable size it states with voltage, cores, conductor, each layer with its nominal and smallest thickness, screen and armour data, diameters and the claimed standards, each with the page and the row it was read from, the values that could not be read and the ones the reader is unsure of. The reading is done by an LLM (Claude) and shown as read; it decides nothing. Each construction is ready for check_cable / POST /api/v1/check, and with standard set every row is checked by the deterministic rule engine in the same call, each rule with its clause and source. Review the values before relying on a verdict. (2 USDC on Base)POST/api/v1/prep— The cable end preparation: in full, each step with the design's own cut depths and the diameter left, the makers' cut-back lengths for this voltage and size (each with its maker), for an MV design the kinds of termination and joint kit that fit it (kits: their ranges, length and shed count from the makers' public catalogues, no maker or kit named) and the outdoor termination's minimum creepage per pollution class a to e (creepage: IEC TS 60815-3 reference USCD times Um/√3, with its corrections and sources), and the step sheet (PDF); the free verdict is the common step order every visitor sees, each step with its sources. Without full and without payment the answer is the verdict a visitor sees on the site, counted against the designs' daily free allowance; full: true (or any paid call) answers in full. A separate paid call at its own price. $0.50 per calculation in USDC with x402; the free verdict counts against the designs' 2 free calls per caller per UTC day; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/drum/loading— The drum page's loading planner: how many vehicles of a type (box trailer, curtain-sider, open top, flat rack, containers, platform, rigid truck, or a custom box in full mode) a number of drums needs, by space and by payload, the rows and positions, chocks and bedding, the securing (wedges, blocking along the axis, tipping, wandering lashings, the load's centre of gravity; EN 12195-1 as the EU guidelines quote it) and every vehicle type compared, each vehicle with its sources. Without full and without payment the answer is the verdict a visitor sees on the site, counted against the designs' daily free allowance; full: true (or any paid call) answers in full. $0.50 per calculation in USDC with x402; the free verdict counts against the designs' 2 free calls per caller per UTC day; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/spec— Write the cable specification for a tender: one cable, or a project of up to 30 cables, each as design_cable takes it (a sentence, a bare designation, a spec or a design), plus the project's requirements (rodent, termite, UV, cold, oil, watertightness, fire, armour and more, each with the construction chosen to meet it). Returns, per cable, the specification in tender order (scope, standards, construction with each layer's thickness and source, additional requirements with their test methods, tests, marking, drums, documents, deviations) as Markdown and plain text, and the required / offered schedule (GTP) as CSV and as JSON rows: REQUIRED filled from the design with each value's source, OFFERED left for the bidder. The same text a Pro member downloads from the designer, written by the same code. Deterministic, no LLM; a draft to check against the editions in force. $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30; no free allowance. (2 USDC on Base)POST/api/v1/climate— The Pro cold-weather check: the long-term mean daily minimum and mean temperature of a place in a month (NASA POWER monthly data of the place's grid cell, GeoNames places, a stored table: no outside call) against the design's minimum laying temperature with its source, and a verdict: comfortable, marginal, prewarm or unknown. A place by its GeoNames id or by coordinates (its nearest place in the table, with the distance). Always paid: the site shows no free part. $0.50 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/economic— The Pro economic size (the IEC 60287-3-2 method): the energy lost a year in this size and one and two sizes up, its present cost over the years, and the discounted payback of the larger size where its extra cost is given, each step with its formula and source. Always paid: the site shows it to members only. $0.50 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/electrical— The Pro electrical values of a medium or high voltage design: capacitance, charging current, inductive reactance in trefoil and flat, a.c. resistance with the skin and proximity effects (IEC 60287-1-1), dielectric loss and the impulse levels (IEC 60502-2), every value with its source; what no source gives is listed as missing. Always paid: the site shows them to members only. $0.50 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)POST/api/v1/commissioning— The Pro commissioning sheet for a design: the tests after installation of its voltage (the rows of design_cable after_installation, IEC 60502-2 clause 20, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with its voltage, duration and source, as a PDF with fields to record the results. A separate paid call: its own price, never inside the design price. $0.50 per calculation in USDC with x402; no free allowance; a list of up to 50 items at $0.50 per item, one payment. (0.5 USDC on Base)GET/api/v1/decode— Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 30 more coding systems) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. (0.1 USDC on Base)GET/api/v1/equivalents— Find the equivalents of a power cable in other countries' standards ("the Dutch equivalent of this Swedish cable"): the decoded cable is rebuilt under each target rule set (IEC 60502, HD 603, HD 620 sections J/M/D/C/K, BS 5467/6724/7846/6622, EN 50618, HD 627) with the same conductor, section, cores, voltage, screen, armour and sheath, then compared layer by layer with the source of every value. Verdict per standard: equivalent, close (with the differences) or none (with the reason), and the name in that country's letters where sourced. Deterministic, no LLM. Never a statement of interchangeability: the buyer's specification decides. (0.1 USDC on Base)POST/api/v1/decode/batch— Decode up to 500 cable designations in one call (a bill of materials), $0.03 per code. Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 29 more of its 36 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. (0.09 USDC on Base)
First seen · last seen